BVCDS - P-5 GAS MIXTURE

  • MSDS: BVCDS
  • Manufacturer: AIRCO
  • Product Name: P-5 GAS MIXTURE
  • National Stock Number: 6830-00N048308
Product Identification

Product ID:P-5 GAS MIXTURE
MSDS Date:08/02/1989
FSC:6830
NIIN:00N048308
MSDS Number: BVCDS

Responsible Party
AIRCO
575 MOUTAIN AVE
MURRY HILL, NJ 07974
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 201-464-8100

Cage: AIRCO

Contractor
AIRCO INC, AIRCO INDUSTRIAL GASES DIV.
MURRAY HILL, NJ 07974-2006 US

Telephone: 800-424-9300(CHEMTREC)

Cage: 00741

Ingredients

BANDAGE. IMMED FLUSH WITH POTABLE WATER FOR A

RTECS: 9999999ZZ


GET MD IMMEDIATELY .

RTECS: 9999999ZZ


CALL YOUR CLOSEST AIRCO LOCATION.

RTECS: 9999999ZZ


TO INCR THE DISCHARGE RATE OF PROD FROM THE

RTECS: 9999999ZZ


TO PVNT HAZ BACK FLOW INTO THE CYLINDERS. PROTECT

RTECS: 9999999ZZ


DRY, WELL-VENT AREA OF NON-COMBUST CONSTRUCTION

RTECS: 9999999ZZ


DO NOT ALLOW THE TEMP WHERE CYLINDERS ARE STORED TO

RTECS: 9999999ZZ


FIRMLY SECURED TO PVNT FALLING OR BEING KNOCKED

RTECS: 9999999ZZ


SYS TO PVNT FULL CYLINDERS BEING STORED FOR

RTECS: 9999999ZZ


CONSULT COMPRESSED GAS ASSOCIATION'S PAMPHLETS P-1,

RTECS: 9999999ZZ


COMPRESSED GAS CYLINDER OR CNTNR OF A GAS IN

RTECS: 9999999ZZ


TRUNK, VAN OR STATION WAGON. A LEAK CAN RESULT IN A

RTECS: 9999999ZZ


ARGON

CAS: 7440-37-1

RTECS: CF2300000

Fraction By Weight: 95%

OSHA PEL N/K

ACGIH TLV: ASPHYXIANT


15%

CAS: 74-82-8

RTECS: PA1490000

Fraction By Weight: 5%

OSHA PEL N/K

ACGIH TLV: ASPHYXIANT


RAPIDLY EVAPORATING LIQUID. DO NOT WASH THE EYES

RTECS: 9999999ZZ


OF CONTAM. OPEN EYELIDS WIDE TO ALLOW LIQ TO

RTECS: 9999999ZZ


OPTHALMOLOGIST FOR TREATMENT AND FOLLOW UP. IF THE

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: BOTH ARGON & METHANE ARE SIMPLE
ASPHYXIANTS. OXYGEN LEVELS SHOULD BE MAINTAINED AT GREATER THAN
19.5% AT NORMAL ATMOSPHERIC PRESSURE WHICH IS EQUIVALENT TO A
PARTIAL PRESSURE OF 135 MMHG. HIGH CONCS OF P-5 GAS MIX SO AS TO
EXCLUDE AN ADEQ SUPPLY OF OXYGEN TO THE LUNGS CAUSES DIZZ, DEEPER
BRTHG (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:DUE TO AIR HUNGER, POSSIBLE NAUS &
EVENTUAL UNCON. P-5 GAS MIXTURE IS RELATIVELY INACTIVE BIOLOGICALLY
& ESSENTIALLY NONTOXIC; THERFORE, THE MAJOR HAZARD IS THE EXCLUSION
OF AN ADEQ SUPPLY OF OXYGEN OF THE LUNGS. SKIN/EYE: CONTACTWITH
LIQUID PROD MAY CAUSE TISSUE FREEZING.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:PROMPT MED ATTN IS MANDATORY IN ALL CASES OF OVEREXP.
RESCUE PERSONNEL SHOULD BE EQUIPPED W/SCBA. VICTIMS SHOULD BE
ASSISTED TO AN UNCONTAM AREA & INHALE FRESH AIR. QUICK REMOVAL FROM
THE CONTAM AREA IS MOST IMPORTANT. UNCONS PERSONSSHOULD BE MOVED
TO AN UNCONTAM AREA, & IF BRTHG HAS STOPPED, ADMIN ARTF RESP &
SUPPLEMENTAL OXYGEN. FURTHER TREATMENT SHOULD BE SYMPTOMATIC &
(SUPP DATA)

Fire Fighting

Flash Point:GAS
Lower Limits:ING 2
Upper Limits:ING 2
Extinguishing Media:EXTINGUISHING MEDIA APPROPRIATE FOR SURROUNDING
FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:ELECTRICAL CLASSIFICATION: NONHAZARDOUS.

Accidental Release

Spill Release Procedures:EVAC ALL PERSONNEL FROM AFFECTED AREAS. USE
APPROP PROT EQUIP. IF LEAK IS IN USER'S EQUIP, BE CERTAIN TO PURGE
PIPING W/AN INERT GAS PRIOR TO ATTEMPTING REPAIRS. IF LEAK IS IN
CNTNR OR CNTNR VALVE, CO NTACT CHEMTREC FOR EMERG ASSISTANCE OR
(ING 9)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:USE ONLY IN WELL-VENT AREAS. VALVE
PROT CAPS MUST REMAIN IN PLACE UNLESS CNTNR IS SECURED W/VALVE PROT
OUTLET PIPED TO USE POINT.
Other Precautions:DO NOT DRAG, SLIDE OR ROLL CYLINDERS. USE A SUITABLE
HAND TRUCK FOR CYLINDER MOVEMENT. USE A PRESSURE REDUCING REGULATOR
WHEN CONNECTING CYLINDER TO LOWER PRESSURE (<3000 PSIG) PIPING OR
SYSTEMS. DO N OT HEAT CYLINDER BY ANY MEANS (ING 10)

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED POSITIVE PRESSURE AIR LINE
WITH MASK OR SCBA SHOULD BE AVAILABLE FOR EMERGENCY USE.
Ventilation:USE LOCAL EXHAUST TO PVNT ACCUM OF HIGH CONCS SO AS TO
REDUCE THE OXYGEN LEVEL IN THE AIR TO LESS THAN 19.5%.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPVD SAFETY GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRST AID PROC: SUPPORTIVE. SKIN: FOR DERMAL CNTCT/FROSTBITE:REMOVE
CONTAM CLTHG & FLUSH AFFECTED AREAS W/LUKEWARM WATER. DO NOT USE
HOT WATER. A PHYSICIAN SHOULD SEE THE PATIENT PROMPTLY IF THE CRYOG
ENIC "BURN" HAS RESULTED IN BLISTERING OF THE DERMAL SURFACE OF
DEEP TISSUE FREEZING. EYE: NEVER INTRODUCE (ING 3)

Chemical Properties

Vapor Density:1.3
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS, ODORLESS GAS.

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE KNOWN.

Disposal

Waste Disposal Methods:DO NOT ATTEMPT TO DISPOSE OF WASTE OR UNUSED
QTYS. RETURN IN THE SHIPPING CNTNR PROPERLY LABELED, WITH ANY VALVE
OUTLET PLUGS OR CAPS SECURED & VALVE PROT CAP IN PLACE TO AIRCO FOR
PROPER DISP. DISP M UST BE I/A/W FED, STATE & LOC REGS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.